ON STAGE 400P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 61

Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online

IEC 60950-1 (ed.1)
 
 
- Page 4 of 8 - 
 
 
www.nemko.com
 
Report No.   100711 
 
 
TRF No. IECEN60950_1C 
 
 
4.7.201 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall not be carried out on parts of 
material classified at least FH-3 according to ISO 
9772 provided that the sample tested was not 
thicker than the relevant part. 
4.7.201.3 Testing of insulating materials 
Parts of insulating material supporting 
POTENTIAL IGNITION SOURCES 
shall be 
subject to the glow-wire test of AS/NZS 
60695.2.11 which shall be carried out at 750°C 
The test shall also be carried out on other parts of 
insulating material which are within a distance of 3 
mm of the connection. 
NOTE: Contacts in components such as switch contacts 
are considered to be connections. 
For parts which withstand the glow-wire test but 
produce a flame, other parts above the connection
within the envelope of a vertical cylinder having a 
diameter of 20 mm and a height of 50 mm shall be 
subjected to the needle-flame test. However, parts 
shielded by a barrier which meets the needle-
flame test shall not be tested. 
The needle-flame test shall be made in 
accordance with AS/NZS 4695.2.2 with the 
following modifications: 
All materials have suitable flame 
class, no testing required. 
Page of 87