Test Report issued under the responsibility of 
 
 
 
 
 
 
 
www.nemko.com 
 
 
This Test Report , when bearing the Nemko name and logo is only valid when issued by a Nemko 
laboratory, or by a laboratory having special agreement with Nemko. 
  
TEST REPORT 
IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 
Information technology equipment – Safety –  
Part 1: General requirements
 
Report Reference No
. ....................: 
100711
 
Date of issue ....................................: 
26 March 2008
 
Total number of pages ...................... 
Refer to page 6
 
CB/CCA Testing Laboratory Name
 :
Nemko Hong Kong Ltd.
 
Phone: 
(+852) 2675 0288
Address ...........................................:
Unit 3-5, 1/F, Festigood Centre, 8 Lok Yip Road, On Lok 
Tsuen,Fanling, N.T., Hong Kong
 
Applicant’s name
............................:
Harman Multimedia
 
Address ............................................:
 
Manufacturer’s name
.....................:
Harman Multimedia
 
Address ............................................:
Same as above 
Factory’s name
...............................:
Harman JBL(Suzhou) Ltd.
 
Address ............................................:
3, Jinshan Road, Suzhou New District, Jiangsu Province, 215011, 
China 
Test specification: 
 
Standard...........................................:
 
 IEC 60950-1:2005 (2nd Edition) and 
 
 EN 60950-1:2006 
Test procedure .................................:
CB  
Non-standard test method…………..:
N/A 
Test Report Form No
. ....................:
IECEN60950_1C 
Test Report Form(s) Originator....................... :
SGS Fimko Ltd  (Nemko) 
Master TRF..................................................... :
Dated 2007-06  (2008 02) 
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as 
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from 
the reader's interpretation of the reproduced material due to its placement and context. 
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme 
procedure shall be removed. 
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended 
to a CB Test Certificate issued by an NCB in accordance with IECEE 02. 
 
If this Test Report Form is used by non-CCA members, the CIG logo and the reference to the CCA Procedure shall be 
removed. 
This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and 
appended to a CCA Test Certificate issued by an NCB in accordance with CCA
 
 
 
 
- Page 2 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
Test item description .....................:
Computer Speaker system
 
Trade Mark .......................................:
 
Manufacturer ....................................:
Harman Multimedia
 
Model/Type reference ......................:
JBL on stage 400 ID
 
Ratings .............................................:
2.3 A, 24 Vdc
 
 
Name and address of production-sites (Factories): 
 
Harman JBL (Suzhou) LTD. 
3, Jinshan Road, Suzhou New District, Jiangsu Province, 215011, China 
 
 
 
 
 
 
- Page 3 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
Testing procedure and testing location: 
  CB/CCA Testing Laboratory
Nemko Hong Kong Ltd.
 
Testing location/ address ...................... : 
Unit 3-5, 1/F, Festigood Centre, 8 Lok Yip Road, On Lok 
Tsuen,Fanling, N.T., Hong Kong 
  Associated CB Laboratory: 
 
Testing location/ address ...................... : 
 
 
 
Tested by (name + signature)..... : 
Pat Leung
 
 
 
Approved by (+ signature)........... : 
Sam-Geun Gwack
 
 
  Testing procedure: TMP 
 
 
Tested by (name + signature)..... : 
 
 
 
Approved by (+ signature)............ :  
 
Testing location/ address ...................... : 
 
 
  Testing procedure: WMT 
 
 
Tested by (name + signature)..... : 
 
 
 
Witnessed by (+ signature) .......... : 
 
 
 
Approved by (+ signature)........... : 
 
 
Testing location/ address ...................... : 
 
 
  Testing procedure: SMT 
 
 
Tested by (name + signature)..... : 
 
 
 
Approved by (+ signature)............ :  
 
 
Supervised by (+ signature) ........ : 
 
 
Testing location/ address ................: 
 
 
  Testing procedure: RMT 
 
 
Tested by (name + signature)..... : 
 
 
 
Approved by (+ signature)............ :  
 
 
Supervised by (+ signature) ........ : 
 
 
Testing location/ address ...................... : 
 
 
 
 
 
- Page 4 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
Summary of testing: 
Tested according to national requirements 
for the following countries: 
All CENELEC members as listed in EN 60950-1:2006. 
All CB members as listed in CB Bulletin 112A, December  
2006. 
At the time of issuing this report only limited countries are 
listed for IEC60950-1: 2005, therefore in addition, country 
deviations for IEC60950 3rd and IEC60950-1:2001 edition 
are included. 
List from IEC 60950-1: 2001 edition: 
Australian differences: CB Bulletin No.112A, Dec 2006.  
Canadian differences: CB Bulletin No.112A, Dec 2006.  
US differences: CB Bulletin No.112A, Dec 2006. 
Singapore differences: CB Bulletin No.112A, Dec 2006.  
Korean differences: CB Bulletin No.112A, Dec 2006. 
Israeli differences: (not related to CB Bulletin No.112A, 
December 2006). 
Japanese differences: CB Bulletin No.112A, Dec 2006. 
Chinese differences: CB Bulletin No.112A, Dec 2006. 
 
General: 
Normal load as described in Annex L or as 
close as possible to the most severe 
normal use. 
Normal operation is considered 1/8th of maximum 
undistorted power.  Non-clipping was determined using a 1 
KHz sinusoidal signal input. For maximum normal operation, 
1/8th of the non-clipping amplitude was used with a filtered 
pink noise input signal. 
 
1.5, 2.5. 3.2 External Power Supply 
The external power supply was not evaluated as part of this 
report. An external power supply approved to IEC 60950 shall 
be provided. The external power supply The external power 
supply output shall be separately certified as limited power 
source, complying with the national regulations of the 
countries in which the appliance is to be sold. 
 
1.7.2 Safety instructions, required markings 
regarding use of a specified power supply 
Class III Equipment with an enclosure made of V-2 material, 
using a non-special connector for the DC input must have a 
marking stating the manufacturer and model number of the 
power supply to be used. Marking is provided. 
 
1.7.12 Language of safety 
markings/instruction 
Instructions and equipment marking related to safety 
shall be applied in a language, which is acceptable in the 
country in which the equipment is to be sold. 
 
 
 
 
- Page 5 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
Copy of marking plate: 
 
 
 
 
- Page 6 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
List of attachments: 
 
Main test report (53 pages) 
Photos (4 pages) 
Australian differences (8 pages) 
Canadian differences (5 pages) 
Chinese differences (1 pages) 
Israeli differences (1 pages) 
Japanese differences (7 pages) 
Korean differences (1 pages) 
Singapore differences (2 pages) 
US differences (5 pages) 
 
 
 
- Page 7 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
Test item particulars
.................................................. :  
Equipment mobility .................................................... : [X] movable     [] hand-held       [] transportable 
[] stationary  [] for building-in  [] direct plug-in 
Connection to the mains ........................................... : [] pluggable equipment   [] type A   [] type B 
[] permanent connection 
[] detachable power supply cord      
[] non-detachable power supply cord 
[X] not directly connected to the mains 
Operating condition ................................................... : [X] continuous 
[] rated operating / resting time:  
Access location  ........................................................ : [X] operator accessible 
[] restricted access location 
Over voltage category (OVC) ................................... : [] OVC I     [] OVC II     [] OVC III     [] OVC IV 
[] other:  
Mains supply tolerance (%) or absolute mains supply 
values ....................................................................... :
N/A 
Tested for IT power systems .................................... : [] Yes     [] No 
IT testing, phase-phase voltage (V) ......................... :
N/A 
Class of equipment ................................................... : [] Class I     [] Class II     [X] Class III      
[] Not classified 
Considered current rating (A) ................................... :
2.3A
 
Pollution degree (PD)  ............................................... : [] PD 1     [X] PD 2     [] PD 3 
IP protection class .................................................... : IP 20 
Altitude during operation (m) .................................... :  
Altitude of test laboratory (m) ................................... :  
Mass of equipment (kg) ............................................ :
1.8kg 
Dimensions: 230mm x 360mm x 110mm
 
Possible test case verdicts: 
 
- test case does not apply to the test object .................: N/A 
- test object does meet the requirement.......................: P (Pass) 
- test object does not meet the requirement.................: F (Fail) 
Testing
..........................................................................:  
Date of receipt of test item ............................................:
February 2008
 
Date(s) of performance of tests ....................................:
February 2008
 
 
 
- Page 8 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(See Enclosure #)" refers to additional information appended to the report. 
"(See appended table)" refers to a table appended to the report. 
Note: This TRF includes EN Group Differences together with National Differences and Special 
National Conditions, if any.  All Differences are located in the Appendix to the main body of this TRF.
 
Throughout this report a comma (point) is used as the decimal separator. 
 
General product information:
 
The EUT is a computer stereo system powered by an external SELV source. The EUT is provided with an 
Ipod connection, USB and an auxiliary audio input connection. 
 
Maximum recommended ambient (Tmra): 40°C 
 
Connection to the supply: Not connected to mains supply. 
 
Normal operation condition: Normal operation is considered 1/8th of maximum undistorted power and the 
Ipod 5V charge output is fully loaded to its max output power (1.5W). Non-clipping was determined using a 1 
KHz sinusoidal signal input. For maximum normal operation, 1/8th of the non-clipping amplitude was used 
with a filtered pink noise input signal. 
 
1.1.2 - Additional requirements: 
Exposure to extreme temperatures, excessive dust, moisture or vibration; to flammable gases; to corrosive 
or explosive atmospheres: 
This equipment is intended to operate in a "normal" environment (Offices and homes). 
 
Electromedical equipment connected to the patient: 
This equipment is not an electromedical equipment intended to be physically connected to a patient.
 
 
Equipment used in vehicles, ships or aircrafts, in tropical countries, or at elevations > 2000m: 
This equipment is intended to operate in a "normal" environment (Offices and homes). 
 
 
 
 
- Page 9 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
1 GENERAL 
 
 
1.5 Components 
 
1.5.1 General 
 
 
 
Comply with IEC 60950-1 or relevant component 
standard  
(see appended table 1.5.1) 
P
 
1.5.2 
Evaluation and testing of components 
Certified components are 
used in accordance with their 
ratings, certifications and they 
comply with applicable parts 
of this standard. 
Components not certified are 
used in accordance with their 
ratings and they comply with 
applicable parts of IEC 60950 
and the relevant component 
standard. 
Components, for which no 
relevant IEC-standard exists, 
have been tested under the 
conditions occurring in the 
equipment, using applicable 
parts of IEC 60950.
 
P
 
1.5.3 Thermal 
controls 
No thermal controls.
 
1.5.4 Transformers 
Class III equipment to be 
supplied by a separately 
approved power supply with 
an SELV output. Power 
supply not evaluated. Refer to 
Summary of testing. 
1.5.5 Interconnecting 
cables 
The interconnecting cables 
contain only SELV.
 
1.5.6 
Capacitors bridging insulation  
Class III equipment .No 
bridging capacitors. 
1.5.7 
Resistors bridging insulation 
No such components bridging 
double or reinforced 
insulation.
 
1.5.7.1 
Resistors bridging functional, basic or 
supplementary insulation 
 
1.5.7.2 
Resistors bridging double or reinforced insulation 
between a.c. mains and other circuits 
 
1.5.7.3 
Resistors bridging double or reinforced insulation 
between a.c. mains and antenna or coaxial cable  
 
1.5.8 
Components in equipment for IT power systems 
Class III equipment.
 
1.5.9 Surge 
suppressors 
 
 
 
- Page 10 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
1.5.9.1 General 
 
1.5.9.2 
Protection of VDRs 
No VDRs. 
1.5.9.3 
Bridging of functional insulation by a VDR 
 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 
 
1.6 Power 
interface 
 
1.6.1 
AC power distribution systems 
Class III equipment.
 
N
 
1.6.2 Input 
current 
(see appended table 1.6.2)  
P
 
1.6.3 
Voltage limit of hand-held equipment 
Class III equipment.
 
N
 
1.6.4 
Neutral conductor  
Class III equipment.
 
N
 
 
1.7 
Marking and instructions 
 
1.7.1 
Power rating  
Marking not required, 
however the marking is 
located on the outside surface 
of the equipment.
 
P
 
 
Rated voltage(s) or voltage range(s) (V)  .............. :
24 Vdc
 
P
 
 
Symbol for nature of supply, for d.c. only .............. :
IEC 60417-1,symbol 
No.5031, is used.
 
P
 
 
Rated frequency or rated frequency range (Hz) ... :
DC rated
 
N
 
 Rated 
current 
(mA or A)  ....................................... :
2.3 A
 
P
 
 
Manufacturer’s name or trade-mark or identification 
mark ...................................................................... :
 
P
 
 Model 
identification 
or type reference .................. :
JBL on stage 400 ID 
P
 
 
Symbol for Class II equipment only  ...................... :
Class III equipment. 
N
 
 Other 
markings and symbols ................................ :
The additional marking does 
not give rise to 
misunderstandings. 
P
 
1.7.2 
Safety instructions and marking 
Provided with marking 
regarding use of specified 
power supply (Not required), 
refer to Copy of marking 
plate. 
P
 
1.7.2.1 General 
Considered P
 
1.7.2.2 Disconnect 
devices 
Class III equipment. 
1.7.2.3 
Overcurrent protective device 
 
1.7.2.4 
IT power distribution systems 
 

Download JBL ON STAGE 400P (serv.man4) EMC - CB Certificate

Here you can view online and download JBL ON STAGE 400P (serv.man4) EMC - CB Certificate in PDF. ON STAGE 400P (serv.man4) emc - cb certificate will guide through the process and help you recover, restore, fix, disassemble and repair JBL ON STAGE 400P (serv.man4) Audio. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.