ON STAGE 400P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 38

Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online

 
 
- Page 38 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
3.2.1.1 
In the United Kingdom, apparatus which is fitted with a flexible cable or cord and 
is designed to be connected to a mains socket conforming to BS 1363 by means of 
that flexible cable or cord and plug, shall be fitted with a ‘standard plug’ in 
accordance with Statutory Instrument 1768:1994 - The Plugs and Sockets etc. 
(Safety) Regulations 1994, unless exempted by those regulations. 
NOTE ‘Standard plug’ is defined in SI 1768:1994 and essentially means an approved plug 
conforming to BS 1363 or an approved conversion plug. 
3.2.1.1 
In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to 
be connected to a mains socket conforming to I.S. 411 by means of that flexible 
cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory 
Instrument 525:1997 - National Standards Authority of Ireland (section 28) (13 A 
Plugs and Conversion Adaptors for Domestic Use) Regulations 1997. 
3.2.4 
In Switzerland, for requirements see 3.2.1.1 of this annex. 
3.2.5.1 
In the United Kingdom, a power supply cord with conductor of 1,25 mm2 is 
allowed for equipment with a rated current over 10 A and up to and including 13 A.
3.3.4 
In the United Kingdom, the range of conductor sizes of flexible cords to be 
accepted by terminals for equipment with a RATED CURRENT of over 10 A up to 
and including 13 A is: 
• 1,25 mm
2
 to 1,5 mm
2
 nominal cross-sectional area. 
4.3.6 
In the United Kingdom, the torque test is performed using a socket outlet 
complying with BS 1363 part 1:1995, including Amendment 1:1997 and 
Amendment 2:2003 and the plug part of DIRECT PLUG-IN EQUIPMENT shall be 
assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16 and 
12.17, except that the test of 12.17 is performed at not less than 125 °C. Where the 
metal earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the 
requirements of clauses 22.2 and 23 also apply. 
4.3.6 
In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such 
devices shall comply with Statutory Instrument 526:1997 - National Standards 
Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets 
for domestic use) Regulations, 1997. 
5.1.7.1 
In FinlandNorway and Sweden TOUCH CURRENT measurement results 
exceeding 3,5 mA r.m.s. are permitted only for the following equipment: 
• STATIONARY PLUGGABLE EQUIPMENT TYPE A that  
 
○ 
is intended to be used in a RESTRICTED ACCESS LOCATION 
where 
 
 
equipotential bonding has been applied, for example, in a  
  telecommunication 
centre; 
and 
 
○ 
has provision for a permanently connected PROTECTIVE 
EARTHING  
  CONDUCTOR; 
and 
 
○ 
is provided with instructions for the installation of that conductor by a 
  SERVICE 
PERSON; 
• STATIONARY PLUGGABLE EQUIPMENT TYPE B; 
• STATIONARY PERMANENTLY CONNECTED EQUIPMENT. 