ON STAGE 400P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 36

Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online

 
 
- Page 36 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
Annex H 
Replace the last paragraph of this annex by: 
At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the dose 
rate shall not exceed 1 μSv/h (0,1 mR/h) (see NOTE). Account is taken of the 
background level. 
Replace the notes as follows: 
NOTE These values appear in Directive 96/29/Euratom. 
Delete NOTE 2. 
Biblio-
graphy 
Additional EN standards. 
⎯ 
 
ZA 
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR 
CORRESPONDING EUROPEAN PUBLICATIONS 
⎯ 
 
ZB 
SPECIAL NATIONAL CONDITIONS 
⎯ 
1.2.4.1 
In Denmark, certain types of Class I appliances (see 3.2.1.1) may be provided with 
a plug not establishing earthing conditions when inserted into Danish socket-
outlets. 
1.5.7.1 
In FinlandNorway and Sweden, resistors bridging BASIC INSULATION in 
CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements 
in 1.5.7.2. 
1.5.8 
In Norway, due to the IT power system used (see annex V, Figure V.7), capacitors 
are required to be rated for the applicable line-to-line voltage (230 V). 
1.5.9.4 
In FinlandNorway and Sweden, the third dashed sentence is applicable only to 
equipment as defined in 6.1.2.2 of this annex. 
1.7.2.1 
In FinlandNorway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A 
intended for connection to other equipment or a network shall, if safety relies on 
connection to protective earth or if surge suppressors are connected between the 
network terminals and accessible parts, have a marking stating that the equipment 
must be connected to an earthed mains socket-outlet. 
The marking text in the applicable countries shall be as follows: 
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun 
pistorasiaan" 
In Norway: “Apparatet må tilkoples jordet stikkontakt” 
In Sweden: “Apparaten skall anslutas till jordat uttag” 
1.7.5 
In Denmark, socket-outlets for providing power to other equipment shall be in 
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard 
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For 
STATIONARY EQUIPMENT the socket-outlet shall be in accordance with Standard 
Sheet DK 1-1b or DK 1-5a. 
2.2.4 
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex. 
2.3.2 
In FinlandNorway and Sweden there are additional requirements for the 
insulation. See 6.1.2.1 and 6.1.2.2 of this annex. 