ON STAGE 400P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 35

Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online

 
 
- Page 35 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
2.7.1 
Replace the subclause as follows: 
Basic requirements 
To protect against excessive current, short-circuits and earth faults in PRIMARY 
CIRCUITS, protective devices shall be included either as integral parts of the 
equipment or as parts of the building installation, subject to the following, a), b) and 
c): 
a) except as detailed in b) and c), protective devices necessary to comply with the 
requirements of 5.3 shall be included as parts of the equipment; 
b) for components in series with the mains input to the equipment such as the 
supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault 
protection may be provided by protective devices in the building installation; 
c) it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY 
CONNECTED EQUIPMENT, to rely on dedicated overcurrent and short-circuit 
protection in the building installation, provided that the means of protection, e.g. 
fuses or circuit breakers, is fully specified in the installation instructions. 
If reliance is placed on protection in the building installation, the installation 
instructions shall so state, except that for PLUGGABLE EQUIPMENT TYPE A the 
building installation shall be regarded as providing protection in accordance with 
the rating of the wall socket outlet. 
2.7.2 
This subclause has been declared ‘void’. 
⎯ 
3.2.3 
Delete the NOTE in Table 3A, and delete also in this table the conduit sizes in 
parentheses. 
⎯ 
3.2.5.1 
Replace  
“60245 IEC 53” by “H05 RR-F”;  
 
 
“60227 IEC 52” by “H03 VV-F or H03 VVH2-F”;  
 
 
“60227 IEC 53” by “H05 VV-F or H05 VVH2-F2”. 
In Table 3B, replace the first four lines by the following: 
| Up to and including 6  
 
|  
 
 
 
0,75 
a)
  
| Over 6 up to and including 10  |  
(0,75) 
b)
 
 
 1,0 
 | 
| Over 10 up to and including 16   |  
(1,0) 
c)
  
 
1,5    
In the conditions applicable to Table 3B delete the words “in some countries” in 
condition 
a)
In NOTE 1, applicable to Table 3B, delete the second sentence. 
3.3.4 
In Table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with 
the following: 
| Over 10 up to and including 16   |  
1,5 to 2,5  
|  
1,5 to 4  
Delete the fifth line: conductor sizes for 13 to 16 A. 
4.3.13.6 
Add the following NOTE: 
NOTE Z1 Attention is drawn to 1999/519/EC: Council Recommendation on the limitation of 
exposure of the general public to electromagnetic fields 0 Hz to 300 GHz. Standards taking 
into account this Recommendation which demonstrate compliance with the applicable EU 
Directive are indicated in the OJEC.
 
⎯ 