ON STAGE 400P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 37

Read JBL ON STAGE 400P (serv.man4) EMC - CB Certificate online

 
 
- Page 37 of 53 - 
 
 
 Report 
No. 
100711 
 
 
TRF No. IECEN60950_1C 
 
 
2.3.4 
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex. 
2.6.3.3 
In the United Kingdom, the current rating of the circuit shall be taken as 13 A, not 
16 A. 
2.7.1 
In the United Kingdom, to protect against excessive currents and short-circuits in 
the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3 
shall be conducted, using an external protective device rated 30 A or 32 A. If these 
tests fail, suitable protective devices shall be included as integral parts of the 
DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met. 
2.10.5.13 
In FinlandNorway and Sweden, there are additional requirements for the 
insulation, see 6.1.2.1 and 6.1.2.2 of this annex. 
3.2.1.1 
In Switzerland, supply cords of equipment having a RATED CURRENT not 
exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC 
60884-1 and one of the following dimension sheets: 
SEV 6532-2.1991   Plug Type 15  
3P+N+PE   250/400 V, 10 A  
SEV 6533-2.1991   Plug Type 11  
L+N    
250 V, 10 A 
SEV 6534-2.1991   Plug Type 12  
L+N+PE  
250 V, 10 A 
In general, EN 60309 applies for plugs for currents exceeding 10 A. However, a 16 
A plug and socket-outlet system is being introduced in Switzerland, the plugs of 
which are according to the following dimension sheets, published in February 
1998: 
SEV 5932-2.1998   Plug Type 25  
3L+N+PE   230/400 V, 16 A 
SEV 5933-2.1998   Plug Type 21  
L+N    
250 V, 16 A 
SEV 5934-2.1998   Plug Type 23  
L+N+PE  
250 V, 16 A 
3.2.1.1 
In Denmark, supply cords of single-phase equipment having a rated current not 
exceeding13 A shall be provided with a plug according to the Heavy Current 
Regulations, Section 107-2-D1. 
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which 
are intended to be used in locations where protection against indirect contact is 
required according to the wiring rules shall be provided with a plug in accordance 
with standard sheet DK 2-1a or DK 2-5a. 
If poly-phase equipment and single-phase equipment having a RATED CURRENT 
exceeding 13 A is provided with a supply cord with a plug, this plug shall be in 
accordance with the Heavy Current Regulations, Section 107-2-D1 or EN 60309-2.
3.2.1.1 
In Spain, supply cords of single-phase equipment having a rated current not 
exceeding 10 A shall be provided with a plug according to UNE 20315:1994. 
Supply cords of single-phase equipment having a rated current not exceeding 2,5 
A shall be provided with a plug according to UNE-EN 50075:1993. 
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which 
are intended to be used in locations where protection against indirect contact is 
required according to the wiring rules, shall be provided with a plug in accordance 
with standard UNE 20315:1994. 
If poly-phase equipment is provided with a supply cord with a plug, this plug shall 
be in accordance with UNE-EN 60309-2. 
Page of 87