ON BEAT XTREME (serv.man8) - JBL Audio EMC - CB Certificate (repair manual). Page 121

Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online

 
Page 8 of 12
 
Report No.: 171153
 
 
 
 
 
 
 
ATTACHMENT 7 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
15.1.1 
Replacement: 
Replace the paragraph after NOTE 2 by the 
following. 
MAINS socket-outlets and interconnection couplers 
mounted on CLASS 0I and CLASS II apparatus 
shall not permit connection of CLASS I apparatus. 
No mains socket-outlets
 
N/A 
 
Replacement: 
Replace the paragraph before NOTE 3 by the 
following. 
MAINS socket-outlets and interconnection couplers 
mounted on CLASS I apparatus shall be provided 
with protective earthing contacts which are reliably 
connected to the PROTECTIVE EARTHING 
TERMINAL or contact of the apparatus. If not, it 
shall not permit connection of CLASS I apparatus. 
Class II apparatus 
N/A 
 
Replacement: 
Replace NOTE 4 by the following. 
NOTE 4  Socket-outlets not allowing the 
connection of CLASS I apparatus can be designed, 
for instance, similar to IEC 60906-1, standard 
sheets 3-1 or 3-2, or according to IEC 60320-2-2, 
standard sheets D or H. 
 
N/A 
15.1.2 Deletion: 
Delete the following sentence in NOTE.  
An example of a connector not meeting the 
requirements of this sub clause is the so-called 
"banana" plug. 
 
 
15.1.3 Replacement: 
Replace the references, “IEC 60083 [1], IEC 
60320, IEC 60884, IEC 60906” by “JIS C 8282 
(corresponding to IEC 60884), JIS C 8303, IEC 
60320 and IEC 60906”. 
 
N/A 
15.2 Addition: 
Add “and CLASS 0I EQUIPMENT” after the words, 
“CLASS I EQUIPMENT” 
Class II apparatus
 
N/A 
Page of 126
Display