ON BEAT XTREME (serv.man8) - JBL Audio EMC - CB Certificate (repair manual). Page 125

Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online

 
Page 12 of 12
 
Report No.: 171153
 
 
 
 
 
 
 
ATTACHMENT 7 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 Replacement: 
Replace Table 18 by the following. 
Considered 
 
RATED CURRENT 
CONSUMPTION of the 
apparatus 
a
 
Nominal cross-
sectional area 
mm
2
 
up to and including 6 
Over 6 up to and including 10
Over 10 up to and including 16
0,75 
1,5 
a
  The RATED CURRENT CONSUMPTION 
includes currents which can be drawn from 
the socket-outlets providing MAINS power for 
other apparatus. 
 
16.3 Replacement: 
In item a), replace IEC 60885-1 by JIS C 3661-
1:1998. 
No interconnecting cables  
comprising hazardous live  
conductors. 
N/A 
 
Replacement: 
In item b), replace IEC 60227-2 by JIS C 3662-2 
(corresponding to IEC 60227-2). 
 
N/A 
16.5 Addition: 
Add “or CLASS 0I EQUIPMENT used a plug with 
an external earth wire” after the words, CLASS I 
EQUIPMENT. 
Class II apparatus 
N/A 
20.1.2 Replacement: 
In NOTE, replace ISO 1043-1 [19] by JIS K 6899-
1:2000 [19]” 
No wires working at voltages  
> 4kV. 
N/A 
Annex B 
Replacement: 
Replace normative by Informative. 
No TNV circuits
 
N/A 
Annex G 
Replacement: 
Replace IEC 60707 by JIS C 0066:2001 
Replace IEC 60695-2-2 by JIS C 60695-2-2:2000. 
Replace IEC 60695-11-10 by JIS Z 2391:1999. 
 
N/A 
 
Page of 126
Display