Report No.: 171153
 
 
 
 
 
 
 
ATTACHMENT 7 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
16.1
 
Addition: 
Add the following to the last of first paragraph. 
Or mains cords shall be of the sheathed type 
complying with Appendix 1 of Article 1 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance..  
Deletion: 
Delete NOTE 1. 
Replacement: 
Replace the second paragraph by the following.
Compliance is checked by testing MAINS supply 
flexible cords in accordance with JIS C 3662 
(corresponding to IEC60227) or JIS C 3663 
(corresponding to IEC 60245) or Appendix 1 of 
Article 1 of the Ministerial Ordinance on stipulating 
technical requirements for the Electrical Appliance.  
Comply 
 
Replacement: 
In this sub-clause, replace IEC 60227 by JIS C 
3662 (corresponding to IEC 60227). 
In this sub-clause, replace IEC 60245 by JIS C 
3663 (corresponding to IEC 60245). 
 
 
Addition: 
Add the following paragraph after the third 
paragraph. 
An external earth wire of Class 0I equipment shall 
be green/yellow, and the length of the earth wire 
from the plug shall be equal or more than 10 cm. 
Class II apparatus 
N/A 
16.2
 
Replacement: 
Replace the first paragraph by the following. 
Power supply cord conductors complied with JIS C 
3662 (corresponding to IEC 60227) or JIS C 3663 
(corresponding to IEC 60245) shall have a nominal 
cross-sectional area not less than those shown in 
table 18. If power supply cord conductors comply 
with other standards, it shall comply with relevant 
wiring requirements.
 
The cord is 0.75mm²,  
within the current rating.
 