Read JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate online
Page 11 of 12
Report No.: 171153
ATTACHMENT 7
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
16.1
Addition:
Add the following to the last of first paragraph.
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
Deletion:
Delete NOTE 1.
Replacement:
Replace the second paragraph by the following.
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance.
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance.
Comply
P
Replacement:
In this sub-clause, replace IEC 60227 by JIS C
3662 (corresponding to IEC 60227).
3662 (corresponding to IEC 60227).
In this sub-clause, replace IEC 60245 by JIS C
3663 (corresponding to IEC 60245).
3663 (corresponding to IEC 60245).
P
Addition:
Add the following paragraph after the third
paragraph.
paragraph.
An external earth wire of Class 0I equipment shall
be green/yellow, and the length of the earth wire
from the plug shall be equal or more than 10 cm.
be green/yellow, and the length of the earth wire
from the plug shall be equal or more than 10 cm.
Class II apparatus
N/A
16.2
Replacement:
Replace the first paragraph by the following.
Power supply cord conductors complied with JIS C
3662 (corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245) shall have a nominal
cross-sectional area not less than those shown in
table 18. If power supply cord conductors comply
with other standards, it shall comply with relevant
wiring requirements.
Power supply cord conductors complied with JIS C
3662 (corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245) shall have a nominal
cross-sectional area not less than those shown in
table 18. If power supply cord conductors comply
with other standards, it shall comply with relevant
wiring requirements.
The cord is 0.75mm²,
within the current rating.
within the current rating.
P