ON BEAT AIR (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL ON BEAT AIR (serv.man3) EMC - CB Certificate online

 
 
www.tuv.com 
Page 9 of 116 
Report No.: 11023927 001 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
1.5.9 
Surge suppressors 
No such components 
N/A 
1.5.9.1 
General 
 
N/A 
1.5.9.2 
Protection of VDRs 
 
N/A 
1.5.9.3 
Bridging of functional insulation by a VDR 
 
N/A 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
N/A 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 
N/A 
 
1.6 
Power interface 
1.6.1 
AC power distribution systems 
TN power system  
1.6.2 
Input current 
Highest load according to 
1.2.2.1 for this equipment is 
the operation with the 
maximum specified by the 
manual instruction. (see 
appended table 1.6.2)  
1.6.3 
Voltage limit of hand-held equipment 
This appliance is not hand-
held equipment. 
N/A 
1.6.4 
Neutral conductor  
The neutral conductor 
insulated from earth and from 
the body throughout the 
equipment as if it were a line 
conductor 
 
1.7 
Marking and instructions 
1.7.1 
Power rating and identification markings 
See below 
1.7.1.1 
Power rating marking 
 
 
Multiple mains supply connections..........................:  Single power source 
 
Rated voltage(s) or voltage range(s) (V)  .............. :  100-240V~ 
 
Symbol for nature of supply, for d.c. only .............. :  AC source 
N/A 
 
Rated frequency or rated frequency range (Hz)  ... :  50/60Hz 
 
Rated current (mA or A) ........................................ :  1.5A  
1.7.1.2 
Identification markings 
 
 
Manufacturer’s name or trade-mark or identification 
mark  ...................................................................... : 
 
 
Model identification or type reference ................... :  See page 5 
Page of 123
Display