Read JBL ON BEAT AIR (serv.man3) EMC - CB Certificate online
www.tuv.com
Page 11 of 116
Report No.: 11023927 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
1.7.8.3
Symbols according to IEC 60417 ........................ :
N/A
1.7.8.4
Markings using figures ....................................... :
N/A
1.7.9
Isolation of multiple power sources .................... :
Single power source
N/A
1.7.10
Thermostats and other regulating devices ......... :
Such devices not used.
N/A
1.7.11
Durability
The label was subjected to
the permanence of marking
test. The label was rubbed
with cloth soaked with water
for 15 sec. And then again for
15 sec. With the cloth soaked
with petroleum spirit.
After this test there was no
damage to the label. The
marking on the label did not
fade. There was no curling
and lifting of the label edge.
the permanence of marking
test. The label was rubbed
with cloth soaked with water
for 15 sec. And then again for
15 sec. With the cloth soaked
with petroleum spirit.
After this test there was no
damage to the label. The
marking on the label did not
fade. There was no curling
and lifting of the label edge.
P
1.7.12
Removable parts
No removable part.
N/A
1.7.13
Replaceable batteries ......................................... :
No battery provided.
N/A
Language(s) .........................................................:
1.7.14
Equipment for restricted access locations ........... :
Not intended for use in
restricted access locations.
restricted access locations.
N/A
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
No access with test finger and
test pin to any parts with only
basic insulation to ELV or
hazardous voltage.
test pin to any parts with only
basic insulation to ELV or
hazardous voltage.
P
2.1.1.1
Access to energized parts
See above.
P
Test by inspection .................................................:
P
Test with test finger (Figure 2A) ............................:
P
Test with test pin (Figure 2B) ................................:
P
Test with test probe (Figure 2C) ............................:
N/A
2.1.1.2
Battery compartments
No battery compartment.
N/A
2.1.1.3
Access to ELV wiring
No ELV wiring in operator
accessible area.
accessible area.
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
(see appended table 2.10.5)
Click on the first or last page to see other ON BEAT AIR (serv.man3) service manuals if exist.