IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
Symbol for Class II equipment only ...................... : 60417-1-IEC-5172 symbol
marked.
P
Other markings and symbols ................................ : Additional symbol or marking
does not give rise to
misunderstanding.
misunderstanding.
P
1.7.2
Safety instructions and marking
English and Germany version
provide.
(Version in other language will
be provided when submitted
for national approval)
be provided when submitted
for national approval)
P
1.7.2.1
General
P
1.7.2.2
Disconnect devices
Appliance inlet serves as
disconnect device.
disconnect device.
P
1.7.2.3
Overcurrent protective device
Not such equipment.
N/A
1.7.2.4
IT power distribution systems
N/A
1.7.2.5
Operator access with a tool
No operator accessible area
that needs to be accessed by
the use of a tool.
that needs to be accessed by
the use of a tool.
N/A
1.2.7.6
Ozone
Not such equipment.
N/A
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ................................... :
No voltage selector.
N/A
Methods and means of adjustment; reference to
installation instructions ......................................... :
installation instructions ......................................... :
N/A
1.7.5
Power outlets on the equipment .......................... :
No power outlets provided.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
characteristics, cross-reference) .......................... :
Fuse marking provided on
PCB:F1 T3.15A 250V
PCB:F1 T3.15A 250V
P
1.7.7
Wiring terminals
See below.
P
1.7.7.1
Protective earthing and bonding terminals .......... :
Class I equipment. Protective
earthing terminal symbol
marked on appliance inlet.
earthing terminal symbol
marked on appliance inlet.
P
1.7.7.2
Terminals for a.c. mains supply conductors
The equipment with appliance
inlet is intended to use the
detachable type power supply
cord.
inlet is intended to use the
detachable type power supply
cord.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
No d.c. mains supply.
N/A
1.7.8
Controls and indicators
No controls and indicators
N/A
1.7.8.1
Identification, location and marking ..................... :
N/A
1.7.8.2
Colours ................................................................ :
N/A