Page 12 of 116
Report No.: 11023927 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1B
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring in
operator accessible area.
operator accessible area.
N/A
2.1.1.5
Energy hazards .....................................................: The energy does not exceed
240VA between any two
points in accessible connector
of secondary circuit.
points in accessible connector
of secondary circuit.
(see appended table 2.1.1.5.)
P
2.1.1.6
Manual controls
No manual controls.
N/A
2.1.1.7
Discharge of capacitors in equipment
See below
P
Measured voltage (V); time-constant (s) ................: (see appended table 2.1.1.7)
2.1.1.8
Energy hazards – d.c. mains supply
Connected to a.c. mains.
N/A
a) Capacitor connected to the d.c. mains supply ..:
N/A
N/A
2.1.1.9
Audio amplifiers .....................................................: Not such equipment.
N/A
2.1.2
Protection in service access areas
No operator accessible area
that needs to be accessed by
the use of a tool.
that needs to be accessed by
the use of a tool.
N/A
2.1.3
Protection in restricted access locations
Not intended for use in
restricted access locations.
restricted access locations.
N/A
2.2
SELV circuits
P
2.2.1
General requirements
The secondary circuits were
tested as SELV. See 2.2.2 to
2.2.4.
tested as SELV. See 2.2.2 to
2.2.4.
P
2.2.2
Voltages under normal conditions (V) ................... : Between any conductors of
the SELV circuits 42.4 V peak
or 60 V d.c. are not exceeded.
or 60 V d.c. are not exceeded.
See appended table 2.2.
P
2.2.3
Voltages under fault conditions (V) ....................... : Single fault did not cause
excessive voltage in
accessible SELV circuits.
Limits of 71V peak and 120V
d.c. were not exceeded within
0.2 seconds and limits 42.4V
peak and 60V d.c. were not
exceeded for longer than 0.2
seconds.
accessible SELV circuits.
Limits of 71V peak and 120V
d.c. were not exceeded within
0.2 seconds and limits 42.4V
peak and 60V d.c. were not
exceeded for longer than 0.2
seconds.
P
2.2.4
Connection of SELV circuits to other circuits ...... :
See sub-clauses 2.2.2 and
2.2.3. and 2.4.2
2.2.3. and 2.4.2
P