Report No. 702277
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14
COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
N/A
Resistors separately approved .............................. :
No
N/A
14.2
Capacitors and RC units
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. :
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. :
X2: CXAC1
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
N/A
14.2.5
a) Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0.2 A:
compliance with IEC 60384-1, 4.38 category B or
better ...................................................................... :
Only metal-cased capacitors
N/A
b)
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ............................................... :
Only metal-cased capacitors
N/A
Shielded by a barrier per Table 21 ......................... :
No
N/A
14.3
Inductors and windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
ELY
YT-10913
P
Transformers and inductors separately approved :
No
N/A
14.3.2
General
14.3.3, 14.3.4.1 and 14.3.5.1
P
14.3.3
Constructional requirements (complete appended tables or include manufacturers
constructional insulation descriptions)
14.3.3.1
Clearances and creepage distances comply with
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
Prim ary – secondary: 12mm
P
Coil formers and partition walls = 0.4 mm
1.1mm x 3
P