Read JBL E 250P (serv.man2) EMC - CB Certificate online
Page 11 of 44
Report No. 702277
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
13
CLEARANCE AND CREEPAGE DISTANCES
(See appended table 13)
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
13.2
Determination of operating voltage
P
13.3
Clearances
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Circuits not conductively
connected to the mains cannot
cause any shock hazard
connected to the mains cannot
cause any shock hazard
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
Creepage distances greater than table 11 minima
P
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
Click on the first or last page to see other E 250P (serv.man2) service manuals if exist.