E 250P (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 14

Read JBL E 250P (serv.man2) EMC - CB Certificate online

Page 11 of 44
Report No. 702277
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
13
CLEARANCE AND CREEPAGE DISTANCES
(See appended table 13)
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
13.2
Determination of operating voltage
P
13.3
Clearances
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
Circuits not conductively
connected to the mains cannot
cause any shock hazard
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
Creepage distances greater than table 11 minima
P
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
N/A
Page of 56