E 250P (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 11

Read JBL E 250P (serv.man2) EMC - CB Certificate online

Page 8 of 44
Report No. 702277
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
No risk of any wire becoming
detached.
N/A
Vibration test carried out .........................................:
No need, see above
N/A
8.12
This sub-clause is void
-
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges (2N force)
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Mains plug
P
All-pole switch or circuit breaker with >3mm contact
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Test of non-separable thin sheet material
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Determination of Hazardous Live parts
U1: 7mV peak
U2: 3mV peak
P
b) Touch current measured from terminal devices
using the network in annex D ................................ :
P
c) Discharge not exceeding 45
μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
N/A
Page of 56
Display