Read JBL E 250P (serv.man2) EMC - CB Certificate online
Page 7 of 44
Report No. 702277
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Mains transformer
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
This sub-clause is void
-
8.8
Double Insulation: the Basic or Supplementary
insulation > 0.4 mm (mm) .......................................:
insulation > 0.4 mm (mm) .......................................:
Primary wires are double
insulated
insulated
P
Reinforced insulation > 0.4 mm (mm) ....................:
Transformer bobbin
P
Thin sheet insulation used inside the enclosure.
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which meet
10.3 dielectric
10.3 dielectric
N/A
Reinforced insulation, three layers any two which
meet 10.3 dielectric
meet 10.3 dielectric
N/A
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
internal hazardous live conductors and accessible
parts
N/A
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
internal hazardous live parts and conductors
connected to accessible parts
N/A
8.10
Class II Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
conductors connected to accessible parts and the
mains
Primary wires are double
insulated. No secondary wires
can come into contact with
primary parts.
insulated. No secondary wires
can come into contact with
primary parts.
P