E 150P - JBL Audio EMC - CB Certificate (repair manual). Page 48

Read JBL E 150P EMC - CB Certificate online

 
Page 44 of 47 
Report No. 702268 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
Annex B 
Cont.
 
If this insulation forms part of a semiconductor  
component (e.g. an optocoupler), there is no distance 
through insulation requirement for the insulation 
consisting of an insulating compound completely filling 
the casing, so that CLEARANCES and CREEPAGE 
DISTANCES do not exist, if the component passes the 
electric strength test in the accordance with the 
ompliance clause below and in addition:- passes the 
test and inspection criteria of 13.6 with an electric 
strength test of 10.3 using the test voltage of 1.5 kV 
multiplied by 1,6 and 
- is subject to routine testing for electric strength during 
manufacturing, using a test voltage of 1,5 kV (for 
performance of the test see N.2.1).It is permitted to 
bridge this insulation with a capacitor complying with 
IEC 60384-14:1993, subclass Y2.  A capacitor 
classified Y3 according to IEC 60384-14:1993, may 
bridge this insulation under the following conditions: 
- the insulation requirements are satisfied by having a 
capacitor classified Y3 as defined by IEC 60384-14, 
which in addition to the Y3 testing, is tested with an 
Impulse test of 2.5kV defined in IEC 62151, subclause 
6.2.1; 
- the additional testing shall be performed on all the 
test specimens as described in IEC 60384-14; 
- the Impulse test of 2.5kV is to be performed before 
the Endurance Test in IEC 60384-14 in the sequence 
of tests as described in IEC 60384-14. 
Subclause 5.3.2 (Corrigendum 1): 
Add after the fourth dash: 
NOTE - In Sweden, exclusions are applicable for 
equipment which is intended for connection to the 
building installation wiring using screw terminals or 
other reliable means, and for equipment which is 
intended for connection to the building installation 
wiring via an industrial plug and socket -outlet or an 
appliance coupler, or both, complying with IEC 60309 
or with a comparable national standard.
 
 N/A 
 
 
Page of 60