E 150P - JBL Audio EMC - CB Certificate (repair manual). Page 45

Read JBL E 150P EMC - CB Certificate online

 
Page 41 of 47 
Report No. 702268 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
J.2 
After Table J.1 the following is added: 
In Norway, due to the IT power distribution 
system used, the a.c. MAINS supply voltage is 
considered to be equal to the line-to-line voltage, 
and will remain 230 V in case of a single earth 
fault. 
Justification
Based on a use in Norway of an IT power 
distribution system where the neutral is not 
provided. 
 N/A 
Annex B 
Replace NOTE 1 by 
In the CENELEC countries listed in IEC 62151, special 
national conditions apply. 
Add the following: 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151). 
Subclause 4.1.1 (Corrigendum 2): 
Add after the first paragraph: 
NOTE - In Norway, CLASS I equipment which is 
intended for connection to the building installation via a 
non-industrial plug or a non-industrial appliance 
coupler, or both and in addition is intended for 
connection to other equipment or a network shall, if 
safety relies on connection to protective earth or if 
surge suppressors are connected between the network 
terminals and ACCESSIBLE parts, have a marking 
stating that the equipment must be connected to an 
earthed mains socket -outlet. 
The marking text shall be as follows: 
 
"Apparatet skal tilkoples jordet stikkontakt" 
 
Subclause 5.3.1 (Corrigendum 1): 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there are 
additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text is 
identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation forming 
part of a component, it shall at least consist of either 
- two layers of thin sheet material, each of which shall 
pass the electric strength test below, or 
- one layer having a distance through insulation of at 
least 0.4 mm, which shall pass the electric strength test 
below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no distance 
through insulation requirement for the insulation 
consisting of an insulating compound completely filling 
the casing, so that CLEARANCES and CREEPAGE 
DISTANCES do not exist, if the component passes the 
electric strength test in the accordance with the 
compliance clause below and in addition: 
 
N/A 
Page of 60