Page 43 of 47 
Report No. 702268 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 National 
differences 
Sweden 
IEC 60065:2001 + A1 
(See also Group Differences)            
                                                                
CB Bulletin 112 / SE  06  II
 
 
14 
The following is added: 
Switches containing mercury such as thermostats, relays and 
level controllers are not allowed. 
Justification: 
Ordinance (1990:994) on Prohibition in Connection with 
Handling, Importation and Exportation of Chemical Products 
(Certain Cases)
 
 
Annex B 
Replace NOTE 1 by 
In the y CENELEC countries listed in IEC 62151, 
special national conditions apply. 
Add the following: 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151). 
Subclause 4.1.1 (Corrigendum 2): 
Add after the first paragraph: 
NOTE - In Sweden, CLASS I equipment which is 
intended for connection to the building installation via a 
non-industrial plug or a non-industrial appliance 
coupler, or both and in addition is intended for 
connection to other equipment or a network shall, if 
safety relies on connection to protective earth or if 
surge suppressors are connected between the network 
terminals and ACCESSIBLE parts, have a marking 
stating that the equipment must be connected to an 
earthed mains socket -outlet. 
The marking text shall be as follows: 
 
"Apparaten skall anslutas till jordat uttag” 
 
Subclause 5.3.1 (Corrigendum 1): 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there are 
additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text is 
identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation forming 
part of a component, it shall at least consist of either 
- two layers of thin sheet material, each of which shall 
pass the electric strength test below, or 
- one layer having a distance through insulation of at 
least 0.4 mm, which shall pass the electric strength test 
below. 
 
N/A 
Page of 60