Read JBL DSC 1000 EMC - CB Certificate online
Page 35 of 47
Report No: JSH0406744-001.
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
Ambient temperature t2 (
o
C) ...............................:
—
Temperature rise dT of winding:
R
1
(O)
R
2
(O)
dT (K)
Limit dT
(K)
Insulation
class
* The limit value reduced by 10K due to the thermal coupler method used.
7.2
TABLE: softening temperature of thermoplastics
N
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MO)
Required R (MO)
Between mains poles (primary fuse disconnected)
>100
2
Between parts separated by basic or supplementary insulation
>100
2
Between parts separated by double or reinforced insulation
>100
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120
No
Between parts separated by basic or supplementary insulation
2120
No
Between parts separated by double or reinforced insulation
4240
No
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ........... : 100-240
—
Ambient temperature (
o
C) .................................. : 25
—
Monitored point: TR1 insulation tape between primary and secondary.
Under fault conditions specified below
dT (K)
Limit dT (K)
One diode short circuit, fuse FU1 opened immediately.
-
-
EC16 short circuit, fuse FU1 opened immediately.
-
-
PH2 pin 1-2 short circuit, power consumption 26 - 38W, no extreme high
temperature, no hazard.
temperature, no hazard.
57
105 (T130)
PH2 pin 3-4 short circuit, as normal, no hazard.
51
105 (T130)
Click on the first or last page to see other DSC 1000 service manuals if exist.