Read Harman Kardon DRIVE AND PLAY 2 (serv.man3) EMC - CB Certificate online
Report No. 078214R-RFCEP02V01
Page : 20 of 48
Version:1.0
6. Surge
6.1. Test
Equipment
Item Instrument
Manufacturer
Type No/Serial No.
Last Calibration
1
Surge Generator SCHAFFNER
NSG 2050
S/N: 200124-031AR
S/N: 200124-031AR
Nov., 2006
2
No.3 Shielded Room
N/A
Note: All equipments are calibrated every one year.
6.2. Test
Setup
6.3. Test
Level
Item Environmental
Phenomena
Units
Test Specification Performance Criteria
Telecommunication Ports (See
1)
and
2)
)
Surges
Line to Ground
Tr/Th us
kV
1.2/50 (8/20)
± 1
B
Telecommunication Ports in Telecom Centres (See
1)
and
2)
)
Surges
Line to Ground
Tr/Th us
kV
1.2/50 (8/20)
± 0.5
B
AC Input and AC Output Power Ports
Surges
Line to Line
Line to Ground
Tr/Th us
kV
kV
kV
1.2/50 (8/20)
±1
± 2
B
AC Input and AC Output Power Ports in Telecom Centres
Surges
Line to Line
Line to Ground
Tr/Th us
kV
kV
kV
1.2/50 (8/20)
±0.5
± 1
B
Notes:
Applicable only to ports which according to the manufacturer’s may directly to outdoor cables.
Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, no immunity test
shall be required.
Surge
Generator
EUT
Load
PC
Non-Conducted Table
Non-Conducted Table
Click on the first or last page to see other DRIVE AND PLAY 2 (serv.man3) service manuals if exist.