EMC 
Compliance
 
Ltd. 
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO, 449-825,  KOREA                                     
TEL:    82 31 336 9919      FAX :    82 31 336 4767 
This test report shall not be reproduced except in full, Without the written approval.
 
Report No.: EMC-CE-0857 
Page :            6        of      22
7
 
 
3.3  Sample calculation 
 
Conducted Emission 
 
The field strength is calculated by adding the LISN factor, cable loss from the 
measured reading. 
The sample calculation is as follows : 
 
FS = MR + LF + CL   
MR = Meter Reading   
LF = LISN Factor 
CL = Cable Loss 
         
If MR is 30dB, LISN Factor 2dB,  CL 1dB             
The result (MR)    is 
 
30 + 2 + 1 = 33dBuV         
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 