Clause 
Requirement - Test 
Result - Remark 
Verdict
 
TÜV SÜD Product Service GmbH 
Report reference No.:081-61102-000  
Electrical Safety 
F10Y2-X dev.DOC 
Ridlerstr. 65 
2006-11-02 
D-80339 München 
Page 43 of 52 
 
 
 
Test Report National land Group Differences IEC 60065 7
th
 Ed. Rev. 00 / 2006-02 
 
 
Annex B 
5th paragraph - add reference to clause 4.2.1.1 
in IEC 62151. 
Add to 12th paragraph: “The requirements of 
4.2.1.1 shall be replaced by the requirements or 
2.3.1 of UL 60950, Third Edition.” 
13th paragraph, 2nd dash replace with: “In the 
event of a single insulation fault, the voltages on 
the TNV-0 circuits, TNV-1 circuits and accessible 
conductive parts shall not exceed the values 
given in clause 9.1.1.1a of this standard for more 
than 0.2 s. Moreover, the limits values as given in 
11.1 shall not be exceeded. After 0.2 s the 
voltage limits of 4.1.2 (35 V peak, or 60 V d.c.) 
shall apply.” 
Add to 19th paragraph: “Apparatus intended to 
be connected to telecommunication networks 
and having ringing voltages applied to the 
apparatus is subjected to touch current limits in 
accordance with clause 5.1.8.1.1 of UL 60950, 
Third Edition” Add to 21st paragraph: 
“Telecommunication network that uses outside 
cable shall comply with the requirements for 
protection against overvoltage from power line 
crosses per 6.4 of UL 60950, Third Edition” 
Add to 22nd paragraph: “Acoustic tests per 6.5 of 
UL 60950, Third Edition for apparatus containing 
earphone held against the ear.” 
Add to 24th paragraph: “Apparatus shall be 
provided with appropriate markings and 
instructions as described in Annex NAA of UL 
60950, Third Edition.” 
No TNV circuit. 
Annex D 
- Figure D.1 & Note delete reference to IEC 
60990 and add reference to ANSI C101. Add 
touch current value in MIU where MIU = U2 x 2 
(r.m.s. value) 
No applied for.  
Annex G 
- Deleted 
 N 
Annex Q 
- Add: Safety requirements for video apparatus 
for use in health care facilities 
 
Annex R 
- Add: Safety requirements for undercabinet 
apparatus 
 
Annex S 
- Add: Safety requirements for in-wall mounted 
apparatus 
 
Annex T 
- Add: Safety requirements for apparatus with 
projection lamps 
 
Annex U 
- Add: Safety requirements for permanently 
connected apparatus 
 
Page of 52