Read Harman Kardon SB 16 (serv.man9) EMC - CB Certificate online
Clause
Requirement - Test
Result - Remark
Verdict
TÜV SÜD Product Service GmbH
Report reference No.:081-61102-000
Electrical Safety
F10Y2-X dev.DOC
Ridlerstr. 65
2006-11-02
D-80339 München
Page 39 of 52
Test Report National land Group Differences IEC 60065 7
th
Ed. Rev. 00 / 2006-02
17.11.1
- Add: The installation of an accessory of a
skilled person shall be such that: a) The
mechanical positioning is accomplished by
means of tools normally available or by means of
special tools provided by the organization
responsible for providing the apparatus as part of
the installation kit, and b) The electrical
connections are made by using existing terminals
and connections in the apparatus or the building
wiring.
skilled person shall be such that: a) The
mechanical positioning is accomplished by
means of tools normally available or by means of
special tools provided by the organization
responsible for providing the apparatus as part of
the installation kit, and b) The electrical
connections are made by using existing terminals
and connections in the apparatus or the building
wiring.
Added. P
18
- Modification: Non-intrinsically protected picture
tubes shall comply with 18.1, 18.2.2 and 18.3.
tubes shall comply with 18.1, 18.2.2 and 18.3.
Intrinsically protected picture tubes shall comply
with UL 1418 or UL 61965.
with UL 1418 or UL 61965.
Add: “A bulb of a picture tube having a face
diameter of 7.5 cm or more shall be mounted in
an enclosure.
diameter of 7.5 cm or more shall be mounted in
an enclosure.
The enclosure shall have no opening that
exceeds 130 mm2 unless the minor dimension of
the opening is 10 mm or less.”
exceeds 130 mm2 unless the minor dimension of
the opening is 10 mm or less.”
No applied for.
N
18.1
- All tubes shall be mounted such that the
enclosure of the apparatus protects the tube
against the effects of implosion. Delete reference
to clause 18.2.
enclosure of the apparatus protects the tube
against the effects of implosion. Delete reference
to clause 18.2.
18.2, 18.2.1, and 18.2.3 are deleted..19 - Add
reference to 19.2.1. The test of 19.3 is conducted
on 1) apparatus with direct view CRT with 48 cm
diagonal min., 2) apparatus, other than a
speaker, with a mass greater than 47 kg, and 3)
apparatus, other than a speaker, with a mass or
25 kg or greater and a height of 1 m or more. The
tests in 19.1, 19.2 and 19.3 shall not cause the
apparatus to overturn. During the test of 19.2.1,
the apparatus shall not slide.
reference to 19.2.1. The test of 19.3 is conducted
on 1) apparatus with direct view CRT with 48 cm
diagonal min., 2) apparatus, other than a
speaker, with a mass greater than 47 kg, and 3)
apparatus, other than a speaker, with a mass or
25 kg or greater and a height of 1 m or more. The
tests in 19.1, 19.2 and 19.3 shall not cause the
apparatus to overturn. During the test of 19.2.1,
the apparatus shall not slide.
No CRT.
N
19.2.1
- Add: Slide test requirements.
No applied for.
N
19.3
– Replace by Horizontal force stability test
requirements.
requirements.
Table 20 – Add values for horizontal force test
Ditto. N
19.6.
-Add: “or equipment rack mounting”.
Ditto. N
20.1a
- Delete
N
20.1b
- Replace “IEC 60707” with “UL 94”
Add: “-parts such as protection TV lenses,
loudspeaker parts, external accessories, and
fibrous materials less then 0.25 mm thick.”
loudspeaker parts, external accessories, and
fibrous materials less then 0.25 mm thick.”
Replaced. N