HS 500 (serv.man3) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon HS 500 (serv.man3) EMC - CB Certificate online

 
 
Page 8 of 59 
Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 P 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
< 2 mm, no entering 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set control 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
< 5V 
 
If C is not greater than 0,1 μF no test needed 
> 0.2 
μF 
9.1.7 
Enclosure sufficiently resistant to external force 
 P 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 P 
 
Test hook of fig. 4 for 10 s (20 N) 
 
 
30 mm diameter test tool for 5 s (100 or 250 N)  ... : 100N P 
9.2 
No hazard after removing a cover by hand 
Can not be removed by hand 
 
10 INSULATION 
REQUIREMENTS 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. :
(See appended table) 
10.2 Humidity 
treatment 48 h or 120 h  .......................... : 48h, 30
O
C, 93%R.H. 
10.3 
Insulation resistance and dielectric strength 
(See appended table) 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
 
11.2 
Heating under fault condition 
(See appended table) 
 
No hazard from softening solder 
 
11.2.1 
Measurement of temperature rises 
 
11.2.2 
Temperature rise of accessible parts 
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(See appended table) 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N 
Page of 60
Display