Report No: JSH006020710-001  
EN 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
13.2 
Determination of operating voltage 
T501: pin13, 14, 15- pin 5, 6: 
270Vrms, 500Vp 
T502: pin3 - pin 15: 380Vrms, 
580Vp 
13.3 Clearances 
Primary (operating voltage: 
240Vrms) —accessible parts / 
enclosure: 4.0mm required 
Primary (operating voltage: 
270Vrms, 500Vp) —accessible 
parts / enclosure: 4.2mm 
required 
Primary (operating voltage: 
380Vrms, 580Vp) —accessible 
parts / enclosure: 5.1mm 
required 
Primary heat sink —accessible 
parts / enclosure: 5.1mm 
required 
L-N before fuse link:  
2.0mm required 
T501: P—S: 4.2mm required 
T502: P—S: 5.1mm required 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
Measured distance:  
Primary (operating voltage: 
240Vrms) —accessible parts / 
enclosure: >4.5mm  
Primary (operating voltage: 
270Vrms, 500Vp) —accessible 
parts / enclosure: >6.5mm  
Primary (operating voltage: 
380Vrms, 580Vp) —accessible 
parts / enclosure: >10mm  
Primary heat sink —accessible 
parts / enclosure: >10mm 
L-N before fuse link: 3.7mm 
T501: P—S: >6.5mm  
T502: P—S: >8.0mm
 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
Page of 60