Read Harman Kardon HS 500 (serv.man3) EMC - CB Certificate online
Page 6 of 59
Report No: JSH006020710-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
CY1, CY2, CY501, CY502
P
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
N
Separation by Class II isolating transformer
N
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) : N
Reinforced insulation > 0,4 mm (mm) ................... : T501 bobbin:> 0.8mm
T502 bobbin: >0.8mm
Optocoupler U502, U504,
U505: 0.40mm
Enclosure (front panel):
>1.5mm
Separation sheet on internal
enclosure under power board:
0.51mm.
Optocoupler U502, U504,
U505: 0.40mm
Enclosure (front panel):
>1.5mm
Separation sheet on internal
enclosure under power board:
0.51mm.
P
Thin sheet insulation
Inside T501, T502
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
Withstand 2120Vp test.
P
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Withstand 4240Vp test.
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
N
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N
Click on the first or last page to see other HS 500 (serv.man3) service manuals if exist.