Read Harman Kardon HS 500 (serv.man3) EMC - CB Certificate online
Page 12 of 59
Report No: JSH006020710-001
EN 60065
Clause
Requirement - Test
Result - Remark
Verdict
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
No such parts
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No such parts
N
14 COMPONENTS
P
14.1 Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such components
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N
b) Resistors separately approved .......................... :
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. : Y1: CY1, CY2, CY501, CY502
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. : X2: C501, C502, C503
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
No such component
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
EC502 metal case
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
EC502 metal case
N
Shielded by a barrier to V-0 or metal ..................... : N
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................. :
manufacturer's name and type .............................. :
Switching mode transformer
T501: BCK-EC4201
T502: BCK-ER2855
Filter L512, L513:
LCL-ET2812
P
Transformers and inductors separately approved : No
N
14.3.2 General
P