Read Harman Kardon HKTS 210SUB (serv.man2) EMC - CB Certificate online
Page 8 of 12
Report No.1112717
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
9
C22
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 2.8W, I
n
= 53mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 52mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
10
R38
Short circuit T2 = 16K
DT1 = 30K
U1 = 65K
CT1 = 36K
Other temperature
no higher
U1 = 65K
CT1 = 36K
Other temperature
no higher
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 7.3W, I
n
= 76mA U
out
= 0V
The test went on for 2 hours.
11
R38
Short circuit T2 = 16K
DT1 = 24K
U1 = 66K
CT1 = 37K
Other temperature
no higher
U1 = 66K
CT1 = 37K
Other temperature
no higher
U
n
= 198V, P
n
= 44W, I
n
= 0.46A U
out
= 10.8V
Immediately after fault condition
U
n
= 198V, P
n
= 6.8W, I
n
= 83mA U
out
= 0V
The test went on for 2 hours and 10 minutes.
12 BR1
Short
circuit
-
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.41A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
U
n
= 0V, P
n
= 0W, I
n
= 0A U
out
= 0V
U
n
= 0V, P
n
= 0W, I
n
= 0A U
out
= 0V
Fuse activated immediately
13
C1 near U1
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
The test went on for 5 more minutes.
No remarks
Click on the first or last page to see other HKTS 210SUB (serv.man2) service manuals if exist.