Page 5 of 12
Report No.1112717
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
N/A
10.2
Humidity treatment 48 h or 120 h ...........................: 120
h
P
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 10
Min. 2
Between parts separated by basic or supplementary insulation
-
-
* Between parts separated by double or reinforced insulation
>10
Min. 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120
No
Between parts separated by basic or supplementary insulation
-
-
* Between parts separated by double or reinforced insulation
4240
No
* This test includes dielectric strength test 3kV / 1 min. on optocoupler U2.