Report No.1112717
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. 220-240
—
Frequency
(Hz)........................................................ 50/60
—
Ambient
temperature
(
o
C) ...................................... 26 – 27
—
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
1
Apparatus
Maximum no
clip output
power
clip output
power
Transf. T2 = 67K
Transf. T1 = 51K
Heatsink HS2 = 50K
Other temperature
no higher
Transf. T1 = 51K
Heatsink HS2 = 50K
Other temperature
no higher
U
n
= 264V, P
n
= 60W, I
n
= 0.58A U
out
= 18V
After 3.5 hours temperature stabilized
U
U
n
= 264V, P
n
= 58W, I
n
= 0.57A U
out
= 18V
2
C6
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.42A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.7W, I
n
= 47mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
3
C6
Short circuit No heat
development
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
U
n
= 198V, P
n
= 0.6W, I
n
= 36mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
4
C26
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.36A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.8W, I
n
= 48mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 37mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.