HKTS 210SUB (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 8

Read Harman Kardon HKTS 210SUB (serv.man2) EMC - CB Certificate online

Page 6 of 12 
 
Report No.1112717 
  
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ............. 220-240 
— 
 Frequency 
(Hz)........................................................ 50/60 
— 
 Ambient 
temperature 
(
o
C) ...................................... 26 – 27 
— 
 
No 
Component 
Fault 
dT (K) / Component  Other results 
(include description and test duration) 
Apparatus  
Maximum no 
clip output 
power  
Transf. T2 = 67K 
Transf. T1 = 51K 
Heatsink HS2 = 50K 
Other temperature 
no higher 
U
n
 = 264V, P
n
 = 60W, I
n
 = 0.58A U
out
 = 18V 
After 3.5 hours temperature stabilized  
U
n
 = 264V, P
n
 = 58W, I
n
 = 0.57A U
out
 = 18V 
C6 
Short circuit  No heat 
development 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.42A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 264V, P
n
 = 0.7W, I
n
 = 47mA U
out
 = 0V 
 
Went immediately in to protection mode and 
the test went on for 5 more minutes.  
C6 
Short circuit  No heat 
development 
U
n
 = 198V, P
n
 = 44W, I
n
 = 0.48A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 198V, P
n
 = 0.6W, I
n
 = 36mA U
out
 = 0V 
 
Went immediately in to protection mode and 
the test went on for 5 more minutes.  
C26 
Short circuit  No heat 
development 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.36A U
out
 = 10.8V 
U
n
 = 198V, P
n
 = 44W, I
n
 = 0.45A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 264V, P
n
 = 0.8W, I
n
 = 48mA U
out
 = 0V 
U
n
 = 198V, P
n
 = 0.6W, I
n
 = 37mA U
out
 = 0V 
 
Went immediately in to protection mode and 
the test went on for 5 more minutes.  
Page of 16
Display