Read Harman Kardon HKTS 210SUB (serv.man2) EMC - CB Certificate online
Page 7 of 12
Report No.1112717
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
5
C3
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.36A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.7W, I
n
= 47mA U
out
= 0V
U
n
= 198V, P
n
= 0.5W, I
n
= 35mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
6
U2
Short circuit
On the
secondary
side.
On the
secondary
side.
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.44A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.8W, I
n
= 48mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 38mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
7 U2
Short
circuit
On the
primary side.
primary side.
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.4W, I
n
= 45mA U
out
= 0V
U
n
= 198V, P
n
= 0.3W, I
n
= 34mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
8 U2
Disconnect
device on
primary side.
device on
primary side.
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.43A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.8W, I
n
= 49mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 38mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
Click on the first or last page to see other HKTS 210SUB (serv.man2) service manuals if exist.