Read Harman Kardon HKTS 210SUB (serv.man2) EMC - CB Certificate online
Page 9 of 12
Report No.1112717
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
14 U1
(SG3525AP)
Short circuit
Vc – GND
Vc – GND
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
The test went on for 5 more minutes.
No remarks
15 U1
(ICE3B0365J)
Short circuit
Vc – GND
Vc – GND
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.7W, I
n
= 46mA U
out
= 0V
U
n
= 198V, P
n
= 0.5W, I
n
= 34mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
16 U1
(ICE3B0365J)
Short circuit
Vc – D
Vc – D
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
Fuse activated immediately.
17
IC1
Short circuit
pin Vcc – InLA
PWB 34K
IC 19K
Other temperature
no higher
IC 19K
Other temperature
no higher
U
n
= 264V, P
n
= 45W, I
n
= 0.38A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 36W, I
n
= 0.34A U
out
= 6.0V
The test went on for 20 more minutes.
18
C21
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 3.0W, I
n
= 66mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
Click on the first or last page to see other HKTS 210SUB (serv.man2) service manuals if exist.