HKTS 210SUB (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 11

Read Harman Kardon HKTS 210SUB (serv.man2) EMC - CB Certificate online

Page 9 of 12 
 
Report No.1112717 
  
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
No 
Component 
Fault 
dT (K) / Component  Other results 
(include description and test duration) 
14 U1 
 
(SG3525AP) 
Short circuit 
Vc – GND 
No heat 
development 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.34A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.35A U
out
 = 10.8V 
 
The test went on for 5 more minutes. 
No remarks 
15 U1 
(ICE3B0365J) 
 
Short circuit 
Vc – GND 
 
No heat 
development 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.35A U
out
 = 10.8V 
U
n
 = 198V, P
n
 = 44W, I
n
 = 0.45A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 264V, P
n
 = 0.7W, I
n
 = 46mA U
out
 = 0V 
U
n
 = 198V, P
n
 = 0.5W, I
n
 = 34mA U
out
 = 0V 
 
Went immediately in to protection mode and 
the test went on for 5 more minutes. 
16 U1 
(ICE3B0365J) 
 
Short circuit 
Vc – D 
 
No heat 
development 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.34A U
out
 = 10.8V 
U
n
 = 198V, P
n
 = 44W, I
n
 = 0.48A U
out
 = 10.8V 
 
Immediately after fault condition 
Fuse activated immediately. 
17 
IC1  
Short circuit 
pin Vcc – InLA
PWB 34K 
IC 19K 
Other temperature 
no higher 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.38A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 264V, P
n
 = 36W, I
n
 = 0.34A U
out
 = 6.0V 
 
The test went on for 20 more minutes. 
18 
C21 
Short circuit  No heat 
development 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.35A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 264V, P
n
 = 3.0W, I
n
 = 66mA U
out
 = 0V 
 
Went immediately in to protection mode and 
the test went on for 5 more minutes. 
Page of 16
Display