HKTS 11 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 37

Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online

 
Page 31 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
6.1 
Replace 
the entire subclause by: 
Apparatus including a potential source of ionizing 
radiation shall be so constructed that personal 
protection against ionizing radiation is provided 
under normal operating conditions and under 
fault conditions. 
Compliance is checked by measurement under 
the following conditions: 
In addition to the normal operating conditions, all 
controls adjustable from the outside BY HAND, 
by any object such as a tool or a coin, and those 
internal adjustments or pre-sets which are not 
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an 
intelligible picture for 1 h, at the end of which the 
measurement is made. 
NOTE Soldered joints and paint lockings are 
examples of adequate locking. 
The amount of ionizing radiation is regulated by 
European Council Directive 96/29/Euratom of 13 
May 1996. This directive requires that at any 
point 10 cm from the outer surface of the 
apparatus, the dose-rate shall not exceed 1µSv/h 
(0.1 Mr/h) taking account of the background level.
Moreover, the measurement shall be made under 
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is 
maintained for 1 h, at the end of which the 
measurement is made. 
A picture is considered to be intelligible if the 
following conditions are met: 
- a scanning amplitude of at least 70% of the 
usable screen width; 
- a minimum luminance of 50 cd/m² with locked 
blank raster provided by a test generator; 
- a horizontal resolution corresponding to at least 
1.5 MHz in the centre, with a similar vertical 
degradation; 
not more than over flashover per 5 min. 
 N/A 
13.3.1 
Delete 
note 4. 
 N/A 
14  
Delete 
note 4 and note 5. 
 P 
15.1.1 
Delete
 notes 1 and 2. 
 N/A 
15.2 
Delete
 note 2. 
 N/A 
16.1 
Delete
 note 1. 
 N/A 
16.2 
Delete
 the note. 
 N/A 
20 
Delete
 note 2. 
 N/A 
Annex B 
Replace 
note 1 by: 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
 P 
Page of 62