Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online
Page 26 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
9.1
Shock Hazard
P
Under normal operating conditions: > 35Vpk ac / 60V dc
Notes: Reference Annex D
Notes: Reference Annex D
-
CLASS I: (single phase)
AC DC
U1: -
Vpk
-
mA
rms
U1:
-
V
- mA
U2: -
Vpk
- mA rms
CLASS II: (single phase)
AC DC
U1: 0.24V
pk
- mA rms
U1: -
V
- mA
U2: 0.22V
pk
- mA rms
- mA
10.3
TABLE: Insulation Resistance Measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between the poles of the circuit directly connected to
the supply mains.
>10 Min.
2
Reinforced insulation.
>10 Min.
4
10.3
TABLE: Electric Strength Measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Between the poles of the circuit directly connected to the
supply mains.
2120V peak
No
Reinforced insulation.
4240V peak
No