Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online
Page 27 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
11.2 TABLE:
summary
of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ........ :
220-230
—
Frequency
(Hz)................................................... :
50/60
—
Ambient
temperature
(
o
C) ................................. : 21
—
No
Component
Fault
Temp Rise/
Component
Component
Other results
(include description and test duration)
(include description and test duration)
1
Speaker out.
Max
69K/windings max
44K/PCB, heat sink
22K/metal enclosure
Un=253V, Pn= 120W, In= 0.6A.
Test time= 4h.
No high temperatures, no remarks.
2
Speaker
sc
--
Un=253V, Pn= 9W, In= 0.067A. The unit shutdown.
Test time= 30min.
No high temperatures, no remarks.
3 C501 sc
--
Un=253/198V. F501 opened immediately.
No high temperatures, no remarks.
4 Q301
(c-e) sc
--
253V, Pn= 15W, In= 0.1A. Test time: 30 min.
No high temperatures, no remarks.
5 Q302
(c-e) sc
--
253V, Pn= 15W, In= 0.1A. Test time: 30 min.
No high temperatures, no remarks..
6
Q111 (c-e)
sc
--
Un=253V, Pn= 9W, In= 0.067A. The unit shutdown.
Test time= 30min.
No high temperatures, no remarks.
7
PW150D
V+ to AGND
sc --
Un=253/198V. F501 opened immediately.
No high temperatures, no remarks.
8
PW150D
V- to AGND
sc --
Un=253/198V. F501 opened immediately.
No high temperatures, no remarks.