Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
13 
TABLES: clearances and creepage distances 
Rated supply voltage:  220-230 V 
Pollution degree: 
II 
Material Group: 
IIIb 
2 N force on internal parts applied: 
30 N force on outside of conductive enclosure applied: 
 
 
Location 
 
Operating Voltage 
 
Clearance (mm) 
 
Creepage (mm) 
 
 
V rms 
 
V peak 
 
Min 
 
Actual 
 
Min 
 
Actual 
 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. 
 
Primary (ac) to Earth (B) 
 
 
 
 
 
 
 
Primary (+dc) to Earth max (B) 
 
 
 
 
 
 
 
Primary (-dc) to Earth max (B) 
 
 
 
 
 
 
 
Across mains fuse (B) 
 
230 
 
345 
 
2.0 
 
8.2 
 
2.3 
 
8.4 
Across primary directly connected to 
the mains (in the main switch)(B) 
 
230 
 
345 
 
2.0 
 
6.1 
 
2.3 
 
6.1 
 
Hazardous live secondary to Earth (B)
 
 
 
 
 
 
Optocoupler input to output (R) 
 
 
 
 
 
 
Primary to Secondary in transformer  
TT0900305570-E (R) 
 
328 
 
463 
 
4.2
 
 
>10 
 
6.9 
 
>10 
Primary to Secondary in transformer  
150-r4055904-e (R) 
 
328 
 
463 
 
4.2
 
 
>10 
 
6.9 
 
9.0 
Primary to Secondary in transformers
  
TD-230-0250K (R)
 
 
325 
 
460 
 
4.5 
 
>10 
 
6.9 
 
7.1 
Primary to accessible conductive 
parts (R) 
 
230 
 
345 
 
4.0 
 
>10 
 
4.6 
 
6.0 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. 
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in 
Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed 
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the 
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an 
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth 
via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from 
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 
or 10 as required, then the value for clearance is used as the minimum creepage distance . 
 
"Min" = minimum required.
 
"Actual = Actual dimensions measured. 
 