HKTS 11 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 31

Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online

 
Page 25 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
7.1 TABLE: 
temperature 
rise measurements: Conditions 
 
Power consumption in the OFF/Stand-by mode   
 
 
of the functional switch (W) ................................: 0W in OFF mode 
— 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
V out 
Pout (W) 
Operating Condition 
253 
50 
0.22 
44 
9.2 
21 
1/8 of max non-clipping output 
power (pink noise). Input signal 
connected to ’Line in L/R’ 
 
 
Loudspeaker impedance (Ω) .............................: 4 
— 
 
Several loudspeaker systems 
Built-in speaker 
 
 
Marking of loudspeaker terminals 
High Level  in/out 
 
Temperature Rise dT of Part
 
dT (K) 
Limit dT (K) 
Test Condition No. 
No 1 
No ___ 
No ___ 
 
Toroid transformer outside. 
20 
 
 
Supply wiring insulation (Not under 
mechanical stress.) 
15 
 
 
60 (50)*  
PCB 41 
 
 
85 (75)* 
Buttons (plastic) 
14 
 
 
50 (40)* 
Enclosure (wood) 
<10 
 
 
60 (50)* 
Enclosure (metal) 
20 
 
 
40 (30)* 
 
Winding temperature rise measurements 
Ambient temperature t1 (
o
C) ............................. :
21 
— 
— 
— 
— 
Ambient temperature t2 (
o
C) ............................. :
21 
— 
— 
— 
— 
Temperature rise dT of winding: 
(
) (
)
1
2
1
5
,
234
1
1
2
t
t
t
R
-R
R
dT
+
×
=


 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT 
(K) 
Insulation 
class 
Transformer Primary winding 
9.291 9.952  18 85 (75)*  
Transformer Sec. winding red-red 
1.518 1.619  17 85 (75)* 
 
()* Permissible temperature rises for tropical climates. 