Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
N/A 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved 
 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to  
IEC 60127 
 
N/A 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ...:  T10AL 250V 
14.5.2.3 
Not possible to connect fuses in parallel ................:   
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  .........: 
 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 
N/A 
14.6 
Switches 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
V-0 compliance with annex G, G.1.1 
and 
Peak inrush rating of switch 
Measured/calculated inrush…………………………: 
 
 
 
 
 
 
 
Relay RAY1 91A at 132V 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1 
 
N/A 
 
Switch controlling > 0.2A with open contact voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1 
 
N/A 
 
Switch controlling = 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 
 
N/A 
Page of 64