Read Harman Kardon HK 990 (serv.man4) EMC - CB Certificate online
Page 14 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
N/A
14.5.2.2
Correct marking of fuse-links adjacent to holder ...: T10AL 250V
P
14.5.2.3
Not possible to connect fuses in parallel ................:
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
replacing fuse-links without the use of a tool .........:
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
and
Peak inrush rating of switch
Measured/calculated inrush…………………………:
Relay RAY1 91A at 132V
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N/A
Switch controlling = 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
N/A
Click on the first or last page to see other HK 990 (serv.man4) service manuals if exist.