Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
Can not come into contact with 
hazardous live parts 
9.1.4 
Terminal devices - within 25mm tested with 
1 mm x 20 mm test pin (10 N); test probe D of IEC 
61032 
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  : 
 
<10V 
 
If C is not greater than 0.1 μF no test needed 
 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
a) 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
b) 
Test hook of fig. 4 for 10 s (20 N) 
 
c) 
Conductive enclosure: 30 mm diameter test tool for 
5 s (100 or 250 N) ...................................................: 
 
9.2 
No hazard 2s after removing a cover by hand 
 
N/A 
 
10 INSULATION 
REQUIREMENTS 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation .................................................................: 
 
10.2 Humidity 
treatment 48 h or 120 h ...........................:  48h 
10.3 
Insulation resistance and dielectric strength 
between mains terminals 
 
 
Insulation resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) 
 
N/A 
 
Insulation resistance across REINFORCED 
insulation (Class II) 
 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
 
 
No flaming more than 10s 
 
N/A 
 
Soldered terminations not used as protective 
mechanism 
 
N/A 
11.2.1 
Measurement of temperature rises 
 
11.2.2 
Temperature rise of accessible parts 
 