Page 13 of 50
Report No. 902952-1
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14.3.3
Constructional requirements (complete appended tables or include manufacturers
constructional insulation descriptions)
constructional insulation descriptions)
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T1 prim-sec: 3mm
T2/T3 prim-sec: >15mm
T4 prim-sec: >20mm
P
Coil formers and partition walls = 0.4 mm
T1 bobbin prim-sec: 0.9mm
T4 bobbin prim-sec: >1.0mm
T2/T3 three layers of insulating
tape.
T4 bobbin prim-sec: >1.0mm
T2/T3 three layers of insulating
tape.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T4 prim-core: 10mm
P
Coil formers and partition walls = 0.4 mm
T4 bobbin prim-core: 0.9mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P