HK 990 (serv.man4) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 12

Read Harman Kardon HK 990 (serv.man4) EMC - CB Certificate online

 
Page 11 of 50 
Report No. 902952-1 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
13.1 
Clearances in accordance with 13.3 
 
 
Creepage distances in accordance with 13.4 
 
13.2 
Determination of operating voltage 
 
13.3 
Clearances 
 
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
 
N/A 
13.3.4 
Measurement of transient voltages 
 
N/A 
13.4 
Creepage distances 
 
Creepage distances greater than table 11 minima 
 
13.5 
Printed boards 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 
N/A 
 
Page of 64
Display