Read Harman Kardon HK 3770 (serv.man2) EMC - CB Certificate online
Page 18 of 51
Report No 248607.
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.3.4.3
Separating transformers with at least basic insulation Windings of class II
construction used.
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm
> 0,4 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Windings of class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high-voltage components.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
P
Protective devices used within their ratings
Thermal cut-outs and fuse.
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified protective devices
applied (thermal cut-outs and
fuse)
See appended table, list of
critical components.
applied (thermal cut-outs and
fuse)
See appended table, list of
critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
TS92 thermal cut-out is
approved component
according to IEC 60730-1.
See appended table, list of
critical components.
approved component
according to IEC 60730-1.
See appended table, list of
critical components.
P
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
No thermal links
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal device re-settable
by soldering.
by soldering.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuse is approved according
to IEC 60127.
See appended table, list of
critical components.
to IEC 60127.
See appended table, list of
critical components.
P
Click on the first or last page to see other HK 3770 (serv.man2) service manuals if exist.