Read Harman Kardon HK 3770 (serv.man2) EMC - CB Certificate online
Page 6 of 51
Report No 248607.
TRF No. IEC60065K
Calibration
All instruments used in the tests given in this test report are calibrated and
traceable to national or international standards.
Further information about traceability will be given on request.
traceable to national or international standards.
Further information about traceability will be given on request.
Measurement
uncertainty
uncertainty
Measurement uncertainties are calculated for all instruments and instrument
set-ups given in this report. Calculations are based on the principles given in
the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007 and other relevant
internal Nemko-procedures.
Further information about measurement uncertainties will be given on request.
set-ups given in this report. Calculations are based on the principles given in
the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007 and other relevant
internal Nemko-procedures.
Further information about measurement uncertainties will be given on request.
Evaluation of results
If not explicitly stated otherwise in the standard, the test is passed if the
measured value is equal to or below (above) the limit line, regardless of the
measurement uncertainty. If the measured value is above (below) the limit line,
the test is not passed - ref IEC Guide 115:2007. The instrumentation accuracy is
within limits agreed by IECEE-CTL.
measured value is equal to or below (above) the limit line, regardless of the
measurement uncertainty. If the measured value is above (below) the limit line,
the test is not passed - ref IEC Guide 115:2007. The instrumentation accuracy is
within limits agreed by IECEE-CTL.
Test item particulars .................................................. : AV Receiver
Classification of installation and use....................... : Class II apparatus
Supply Connection ..................................................... : Detachable cord with appliance inlet
....................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A (Not Applicable)
- test object does meet the requirement ................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing:
Date of receipt of test item ........................................ : 2013-10-10
Date (s) of performance of tests ............................... : 2013-10-10 to 2013-11-21
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ...................................................... :
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ...................................................... :
Yes
Not applicable
Not applicable
When differences exist; they shall be identified in the General product information section.
Click on the first or last page to see other HK 3770 (serv.man2) service manuals if exist.