 Report 
No. 
98502 
 
 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
No live shaft, handles or 
levers
 
N/A 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
No access for the test pin
 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
Does not reach hazardous 
live parts
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
Does not reach hazardous  
live parts
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No preset controls
 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s 
 ................................................................................. : 
Measured voltage after  
2 sec: Max. 1 V (peak).
 
 
If C is not greater than 0,1 μF no test needed 
 
N/A 
9.1.7 
a) Enclosure sufficiently resistant to external force  
 
 Test probe 11 of IEC 61032 for 10 s (50 N) 
Test with test finger result 
in no hazard
 
 
b) Test hook of fig. 4 for 10 s (20 N) 
Test with test hook results 
in no hazard.
 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Tested with 100N results  
in no damage.
 
9.2 
No hazard after removing a cover by hand 
No cover removable by 
hand
 
N/A 
 
 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ............................................................... : 
> 100 M
Ω, after surge test 
 
10.2 Humidity 
treatment 48 h or 120 h  ....................... : 
120 h (40
°C).  
No impairment
 
10.3 
Insulation resistance and dielectric strength 
between mains teminals 
See appended table 
 
Insulation Resistance and dielectric strength 
across BASIC or SUPPLEMENTARY insulation 
(Class 1) 
Class II apparatus.
 
N/A 
 
Insulation resistance and dielectric strength 
across REINFORCED insulation (Class II) 
See appended table
 