Read Harman Kardon HK 3390 EMC - CB Certificate online
- Page 12 of 43 -
Report
No.
98502
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
No live shaft, handles or
levers
levers
N/A
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
No access for the test pin
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No preset controls
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s
................................................................................. :
withdrawal of the mains plug; voltage (V) after 2 s
................................................................................. :
Measured voltage after
2 sec: Max. 1 V (peak).
2 sec: Max. 1 V (peak).
P
If C is not greater than 0,1 μF no test needed
N/A
9.1.7
a) Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger result
in no hazard
in no hazard
P
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook results
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Tested with 100N results
in no damage.
in no damage.
P
9.2
No hazard after removing a cover by hand
No cover removable by
hand
hand
N/A
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ............................................................... :
surge test for basic and 4 MΩ min. for reinforced
insulation ............................................................... :
> 100 M
Ω, after surge test
P
10.2 Humidity
treatment 48 h or 120 h ....................... :
120 h (40
°C).
No impairment
P
10.3
Insulation resistance and dielectric strength
between mains teminals
between mains teminals
See appended table
P
Insulation Resistance and dielectric strength
across BASIC or SUPPLEMENTARY insulation
(Class 1)
across BASIC or SUPPLEMENTARY insulation
(Class 1)
Class II apparatus.
N/A
Insulation resistance and dielectric strength
across REINFORCED insulation (Class II)
across REINFORCED insulation (Class II)
See appended table
P
Click on the first or last page to see other HK 3390 service manuals if exist.