Read Harman Kardon HK 3390 EMC - CB Certificate online
- Page 8 of 43 -
Report
No.
98502
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No lionizing radiation.
N/A
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 :
No laser
N/A
Emission limits under fault conditions ............. :
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
No fuse links operate during
normal operating operation.
See appended table
normal operating operation.
See appended table
P
7.1.1
Temperature rise of accessible parts
See appended table
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
See appended table
P
7.1.3
Temperature rise of parts acting as a support or
as a mechanical barrier
as a mechanical barrier
See appended table
P
7.1.4
Temperature rise of windings
See appended table
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
See appended table
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Approved components
according to relevant IEC
standards.
according to relevant IEC
standards.
N/A
Click on the first or last page to see other HK 3390 service manuals if exist.