Read Harman Kardon HK 3390 EMC - CB Certificate online
- Page 10 of 43 -
Report
No.
98502
Reinforced
insulation > 0,4 mm (mm) ............... :
Bobbins of main and sub
transformer, ref. 14.3.
transformer, ref. 14.3.
P
Thin sheet insulation (excluding non-separable
thin sheet insulation. See 8.22)
thin sheet insulation. See 8.22)
No thin sheet insulation
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated.
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Single insulation but
safely anchored.
safely anchored.
P
8.10
Double insulation between conductors connected
to the mains and accessible parts.
to the mains and accessible parts.
Double insulation between internal hazardous
live parts and conductors connected to accessible
parts.
live parts and conductors connected to accessible
parts.
Double insulated,
tested according to 8.9
and 10.3.
tested according to 8.9
and 10.3.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires are
connected with
multi-contact housing.
connected with
multi-contact housing.
P
Vibration
test
carried out ..................................... :
See 12,1,2
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
Covers adequately
fastened with screws.
fastened with screws.
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
Wires safely anchored
away from parts with high
temperature.
away from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
Click on the first or last page to see other HK 3390 service manuals if exist.