Read Harman Kardon HK 3390 EMC - CB Certificate online
- Page 6 of 43 -
Report
No.
98502
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ............................. :
Class II apparatus
—
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
No test box required.
Tested according to
manufacturer’s instructions
Tested according to
manufacturer’s instructions
N/A
5 MARKING
Comprehensible and easily discernible
On front and rear side of
the enclosure.
the enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / spirit
P
5.1 Identification,
maker, model ............................... :
Maker: “Harman / Kardon”
Model: “HK 3390/230.”
See copy of marking plate
Model: “HK 3390/230.”
See copy of marking plate
P
Class II symbol if applicable
Class II symbol is applied
in according to IEC 60417-
5172
in according to IEC 60417-
5172
P
Rated supply voltage and symbol ...................... :
“220V-230V” or “220V”
and AC-symbol (
~
) used.
P
Frequency if safety dependant
“50/60 Hz” or “60Hz”
P
Rated current or power consumption ............... :
230W
P
5.2 Earth
terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals.
The output signal will rise to
36Vpeak at maximum out
power if the speaker output
load is disconnected.
No hazard.
36Vpeak at maximum out
power if the speaker output
load is disconnected.
No hazard.
P