                                                                                Page 10 of 51                        Report No. SH08050531-002 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
12.3 
Remote controls with hazardous live parts 
         
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
         
 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
         
 
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
 
Pass 
 
Creepage distances in accordance with 13.4 
 
Pass 
13.2 
Determination of operating voltage 
TR1: pin7- pin 13: 280Vrms, 
900Vp 
Pass 
13.3 
Clearances 
(see appended table) 
Pass 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
N/A 
13.4 
Creepage distances 
(see appended table) 
Pass 
 
Creepage distances greater than table 11 minima 
         
 Pass 
13.5 Printed 
boards 
         
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
         
 
N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
         
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
         
 
N/A 